Description
Fabry Perot Lasers: 6000 nm – 14000 nm
nanoplus offers FP quantum casccade lasers at any wavelength between 6000 nm and 14000 nm.
Key features of nanoplus FP quantum cascade lasers
- spectral multimode
- lateral single mode
- pulsed operation
- room temperature
- custom wavelengths
Why choose nanoplus FP quantum cascade lasers
- precise selection of target wavelength
- typically > 5 mW output power
- small size
- easy usability
- high efficiency
- long-term stability
For more than 15 years nanoplus has been the technology leader for lasers in gas sensing. We produce lasers at large scale at our own fabrication sites in Gerbrunn and Meiningen. nanoplus cooperates with the leading system integrators in the TDLAS based analyzer industry. More than 20,000 installations worldwide prove the reliability of nanoplus lasers.
Quick description of nanoplus FP laser technology
nanoplus uses a unique and patented technology for FP laser diode manufacturing. We follow a ridge waveguide approach, which is independent of the material system.
Related Information for nanoplus FP QCLs between 6000 nm and 14000 nm
Specifications
The following table summarizes the typical FP laser specifications in the 6000 nm to 14000 nm range:
parameters (T = 25 °C) | symbol | unit | minimum | typical | maximum |
---|---|---|---|---|---|
wavelength precision | δ | nm | 5 | 50 | 100 |
average output power | Pavg | mW | 1 | 5 | 20 |
peak output power | Ppeak | mW | 10 | 200 | 1000 |
pulsed operation current | If | mA | 1000 | 3600 | |
pulsed threshold current | lth | mA | 500 | 2000 | |
operating voltage | V | V | 10 | 15 | 20 |
peak slope efficiency | e | mW / A | 200 | 500 | 800 |
repetition frequency | f | kHz | 0.001 | 100 | 2000 |
pulse length | t | ns | 2 | 100 | 3000 |
duty cycle | d. c. | % | 0 | 3 | 10 |
side mode suppression ratio | SMSR | dB | > 30 | ||
slow axis (FWHM) | degrees | 20 | 25 | 30 | |
fast axis (FWHM) | degrees | 50 | 60 | 70 | |
emitting area | W x H | µm x µm | 15 x 4 | 20 x 5 | 30 x 6 |
storage temperature | TS | °C | -40 | 20 | 80 |
operational temperature at case | TC | °C | -20 | +25 | +80 |