Description
Description:
Wavelength of 1.4-2.0 um is less harmful to the human eye, so a laser with this wavelength range is called the human eye-safe laser. This wavelength range is located in the atmospheric transmission window, the absorption and scattering of the laser is only 1/50 of the 1.06um laser, which is of great significance for long distance action, especially for military applications.
Application:
Laser ranging
Laser irradiation
Laser radar
Target recognition
Laser medical treatment
Optical fiber communication
Key Feature:
Beam quality near diffraction limit
Small volume
Low power consumption,
no temperature control
Open and be used
High reliability
Good stability
Wide temperature range
Theory
Small volume
Low power consumption
Good stability
High reliability
Feature
The damage threshold for human eye is high when a
laser with a wavelength greater than 1.4 um, because
when it is irradiated to the human eye, most of its light
intensity is absorbed by the vitreous body, so it is not
easy to damage the retina at a certain power.( Taking the
1.57um laser as an example, according to the US national security standards, its safe exposure to human eye is
400 thousand times that of the 1.06um Nd:YAG laser
currently used.) So it is called the human eye safety
wavelength. In this band, the safest band is located near
1.54um, so there are also people’s eye safety limits to
1.5-1.7um, which has a large contrast to the background
of many targets, such as vehicles, ships, cement buildings, etc., which is very attractive in laser radar, target
recognition and so on
Laser wavelength:1533nm
Pulse Width: 4.3ns
Peak power: 20Kw
Spot size:Φ0.16mm
Divergence angle: 9mrad
Operating temperature: -45˚C – +75˚C
Overall dimension: 26.3×9.9×7.9mm
weight:7g
Energy Stability(RMS,104shots): 0.6%
M-Square: 1.1NA
LD Working Current: 7.5A
LD Working Current pulse width: 1.2ms
LD Working Voltage: 1.7V
Power Consumption:0.017W
Beam Alignment Tolerance (Off-axis Angle):1mrad
Beam Alignment Tolerance (Position(△r)):0.1mm
Storage Temperature:-40 to 80OC
Operating Humidity:5%
Shock: 15g, 0.5ms, 6 shocks/ 3 axes, 2 shocks/axis
Vibration:20~2000Hz, 0.02g2/Hz/ 3 axes, 1hr/axis
Expected Lifetime:2×107
Operating principle
The damage threshold for human eye is high when a laser with a wavelength greater than 1.4 um, because when it is irradiated to the human eye, most of its light intensity is absorbed by the vitreous body, so it is not easy to damage the retina at a certain power.( Taking the 1.57um laser as an example, according to the US national security standards, its safe exposure to human eye is 400 thousand times that of the 1.06um Nd:YAG laser currently used.) So it is called the human eye safety wavelength. In this band, the safest band is located near 1.54um, so there are also people’s eye safety limits to 1.5-1.7um, which has a large contrast to the background of many targets, such as vehicles, ships, cement buildings, etc., which is very attractive in laser radar, target recognition and so on.
Please kindly check the datasheet:
1533nm Eye Safe Laser