Description
- Brand Name: TES
- Certification: CE
- Origin: Taiwan China
- is_customized: Yes
- Orginal of place: from TES Factory in Taiwan
NEW Original Made in Taiwan TES -92 EMF Meter Triaxial Data Logger The Electromagnetic Radiation Detector TES92
Features:
-
50 MHz to 3.5 GHz frequency range.
-
For isotropic measurements of electromagnetic fields.
-
Non-directional (isotropic ) measurement with three-channel measurement probe.
-
High dynamic range due to three-channel digital results processing.
-
Configurable alarm threshold and memory function.
-
Easy to use
|
-
High frequency (RF) electromagnetic wave field strength measurement.
-
Mobil phone base station antenna radiation power density measurement.
-
Wireless communication applications (CW , TDMA , GSM , DECT).
|
-
Wireless LAN (Wi-Fi) detection, installation.
-
Spy camera, wireless bug finder.
-
Cellular/Cordless phone radiation safety level.
-
Microwave oven leakage detection.
-
Personal living environment EMF safety.
-
RF power measurement for transmitters.
|
ELECTRICAL SPECIFICATIONS
|
Sensor type
|
Electric field (E)
|
Frequency range
|
50MHz to 3.5 GHz
|
Directional characteristic
|
Isotropic, 3-dimensional
|
Measurement range (CW signal>50MHz)
|
38mV/m to 11V/m
|
Absolute error(@1V/m and 50MHz)
|
± 1.0dB
|
Frequency response (taking into account typ. CAL factor)
|
± 1.0dB (50MHz to 1.9 GHz) , ±2.4dB(1.9GHz to 35GHz)
|
Isotropy deviation
|
Type. ±1.0dB f>50 MHz
|
Overload limit
|
4.2W/m2 (40 V/m)
|
Temperature response(0 to 50 )
|
± 1.5dB
|
Note
|
Unless otherwise stated, all specifications hold under the following assumptions:
Sinusoidal signals; device in far-field of a source; probe head pointing toward source; ambient temperature +23 ±3 ;relative air humidity 25% to 75%.
|
|
Measurement method
|
Digital , triaxial measurement
|
Directional characteristic
|
Isotropic, triaxial
|
Measurement range selection
|
One continuous range
|
Display resolution
|
0.1mV/m, 0.1 μA/m, 0.1 μW/m², 0.001 μW/cm²
|
Setting time
|
Typically 1s ( 0 to 90% of meas. value)
|
Display refresh rate
|
Typically 400mS
|
Display type
|
LCD 4 digit
|
Audible alarm
|
Buzzer
|
Measurement units
|
mV/m , V/m , μA/m , mA/m , μW/m² , mW/m² , μW/cm²
|
Measurement display value
|
Instantaneous measured value, maximum value or average value since power-on.
|
Measurement average time (in per-set steps)
|
4s to 15 minutes
|
Measurement alarm function
|
Adjustable threshold with ON/OFF
|
Measurement calibration factor CAL
|
Adjustable
|
Manual data memory and read storage
|
99 sets ( only recall by meter )
|
Battery
|
9V
|
Battery life
|
>15 hours
|
Accessory
|
carrying case & manual
|
|
Notes: The package not included batteries